CBMZF - W14-77-4 UNSATURATED POLYESTER RESIN

  • MSDS: CBMZF
  • Manufacturer: ADVANCE COATINGS CO
  • Product Name: W14-77-4 UNSATURATED POLYESTER RESIN
  • National Stock Number: 8030-00N071029
Product Identification

Product ID:W14-77-4 UNSATURATED POLYESTER RESIN
MSDS Date:05/16/1994
FSC:8030
NIIN:00N071029
MSDS Number: CBMZF

Responsible Party
ADVANCE COATINGS CO
DEPOT RD
WESTMINSTER, MA 01473
US

Emergency Phone: 508-342-7459

Info Phone: 508-874-5921

Cage: 3K491

Contractor
ADVANCE COATINGS CO
WESTMINSTER, MA 01473 US

Telephone: 978-874-5921

Cage: 3K491

Ingredients

STYRENE (SARA 313)

CAS: 100-42-5

RTECS: WL3675000

Fraction By Weight: 40%

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM;100 STEL, S

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


POLYESTER RESIN

Fraction By Weight: 60%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:MODERATE IRRITANT.
INHALATION:MUCOUS MEMBRANE IRRITANT. SKIN:MODERATE IRRITANT.
INGESTION:MODERATE HAZARD. CHRONIC:LONGTERM EXPOSURE MAY CAUSE
NAUSEA, LOSS OF APPETITE, CENTRAL NERVOUS SYSTEM DE PRESSION &
GENERAL WEAKNESS.
Explanation of Carcinogenicity:STYRENE:IARC MONOGRAPHS, SUPPLEMENT, VOL
7, PG 345, 1987:GROUP 2B. ANIMAL:NERVOUS SYSTEM.
Effects of Overexposure:OVERXPOSURE MAY CAUSE IRRITATION TO THE
RESPIRATORY TRACT & TEARING OR REDNESS OF THE EYES.
Medical Cond Aggravated by Exposure:THIS MATERIAL OR ITS EMISSIONS MAY
AGGRAVATE PRE-EXISTING CENTRAL NERVOUS SYSTEM DISORDERS.

First Aid

First Aid:INGEST:CALL MD IMMEDIATELY . SKIN:FLUSH W/COPIOUS AMOUNTS OF
WATER. CALL MD . INHAL:REMOVE TO FRESH AIR, REST, KEEP WARM & GET
MEDICAL ATTENTION. EYES:FLUSH W/WARM WATER FOR AT LEAST 15 MI
NUTES. CONSULT MD.

Fire Fighting

Flash Point Method:PMCC
Flash Point:88.0F,31.1C
Lower Limits:1.1%
Upper Limits:6.1%
Extinguishing Media:CARBON DIOXIDE, WATER FOG, WATER FOAM, DRY
CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:RESIN SPRAY FROM SPRAY GUN IS MORE
FLAMMABLE THAN LIQUID RESIN. DRUMS OF RESIN IF HEATED IN A FIRE MAY
POLYMERIZE & BUILD UP MORE INTERNAL HEAT.

Accidental Release

Spill Release Procedures:ABSORB W/VERMICULITE, SAWDUST OR RAGS OR SCOOP
UP W/SCOOPS OR SHOVELS. CLEAN UP RESIDUE W/STRONG DETERGENT WATER
SOLUTIONS. (GLOVES & GOGGLES). DO NOT ALLOW IN SEWER SYSTEM.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID HEAT & FLAMES. ALWAYS USE UP
OLDEST LOT FIRST. MATERIAL SHOULD LAST 6 MONTHS AT NOT OVER 75F.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED ORGANIC VAPOR RESPIRATORS
ARE RECOMMENDED IF 50 PPM OF STYRENE IS EXCEEDED.
Ventilation:LOCAL EXHAUST:MAINTAIN VAPOR CONCENTRATION OF STYRENE BELOW
50 PPM.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:USE GOOD PERSONAL HYGIENE PRACTICE.
Supplemental Safety and Health
CNDTNS(POLYM):IGNITE ITSELF.

Chemical Properties

Boiling Pt:B.P. Text:293F,145C
Vapor Pres:4.5 @ 20C
Vapor Density:3.6
Spec Gravity:1.12 (H*2O=1)
Evaporation Rate & Reference:0.7 (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:VISCOUS LIQUID W/ODOR OF STYRENE MONOMER.

Stability

Stability Indicator/Materials to Avoid:YES
NEVER MIX ORGANIC PEROXIDES W/PROMOTERS. THESE MUST BE ADDED TO RESIN
SEPARATELY.
Stability Condition to Avoid:AVOID STORAGE OVER 75F. THIS MAY CAUSE
PREMATURE GELATION.
Hazardous Decomposition Products:ON DECOMPOSITION EMITS ACRID FUMES.
INCOMPLETE COMBUSTION PRODUCES CARBON MONOXIDE.

Disposal

Waste Disposal Methods:LAND FILL SOLIDS OR INCINERATE LIQUIDS
W/COMPATIBLE FUEL WHERE PERMITTED UNDER FEDERAL, STATE & LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.